The construction of high-rise buildings with increasing slenderness ratios presents both economic and engineering challenges. This study investigates the effect of slenderness ratio on the seismic performance of high-rise buildings in various seismic zones across the United States. The research employs non-linear and linear static analysis to assess the seismic response of slender high-rises subjected to ground motions representative of different US seismic zones. Key parameters such as lateral drift, inter-story drift ratio, will be evaluated to understand how slenderness influences building behavior under seismic loads. The findings aim to improve seismic design guidelines, optimize structural systems for slender high-rises, This research contributes to the development of safer, more resilient, and cost-effective high-rise construction practices in earthquake-prone regions. In this study, the author focuses on the behavior of the slenderness of high-rise buildings, taking six models with different width. the behavior of high-rise concrete buildings in various zip codes throughout the USA. The study was done according to ACI 318-14 and ASCE 7-10. A linear and Nonlinear static analysis was carried out using ETABS software. The seismic lateral loading on the flat slab with high-column inertia, with or without edge beams, was taken into consideration.Each model was considered to have a different slenderness ratio due to the height of the building, as the author had 20, 30, and 40 storey buildings, This study presented a design chart for any building dimensions (length and width) to guide the designer to the maximum height that can be achieved in any seismic zone.
Fawzy, S. (2024). The Influence Of Slenderness Ratio On High-Rise Building Seismic Performance Across US Seismic. Engineering Research Journal (Shoubra), 53(3), 201-210. doi: 10.21608/erjsh.2024.286020.1300
MLA
Samy A Fawzy. "The Influence Of Slenderness Ratio On High-Rise Building Seismic Performance Across US Seismic", Engineering Research Journal (Shoubra), 53, 3, 2024, 201-210. doi: 10.21608/erjsh.2024.286020.1300
HARVARD
Fawzy, S. (2024). 'The Influence Of Slenderness Ratio On High-Rise Building Seismic Performance Across US Seismic', Engineering Research Journal (Shoubra), 53(3), pp. 201-210. doi: 10.21608/erjsh.2024.286020.1300
VANCOUVER
Fawzy, S. The Influence Of Slenderness Ratio On High-Rise Building Seismic Performance Across US Seismic. Engineering Research Journal (Shoubra), 2024; 53(3): 201-210. doi: 10.21608/erjsh.2024.286020.1300